FUSION High-Voltage Distribution Unit

The FUSION high-voltage distribution unit can be used to connect the main components battery, charger, inverter, motor and optionally the fast charging system. Typical applications are electrified machines and vehicles with increased demands on robustness and safety, such as construction machinery, commercial vehicles and municipal vehicles.

FUSION800M : High-voltage distribution unit 800 Volt

SUNCAR FUSION 800

Features:

  • 2x connections up to 600 A
  • 4x connections up to 400 A
  • 4x connections up to 150 A
  • 6x connections up to 50 A
  • Mainboard (interlock switch, temperature sensor)
  • Potential equalization
  • EMC glands
  • Pressure compensation element
  • Short-circuit bracket
  • Access measuring tips with additional safety level
  • Insulation monitor (optional)

Specifications:

System voltage

up to 800 VDC

Supply voltage

12 V / 24 V

Fuse protection

Positive pole

System weight

20 kg (fully assembled)

Ambient temperature

-40 - +85 °C

Protection class

IP67*

* higher class on request

Datasheet (PDF)

FUSION450 : High voltage distribution unit 450 Volt

SUNCAR FUSION 450

Features:

  • 4x connections up to 400 A
  • 2x connections up to 125 A
  • 4x connections up to 50 A
  • Mainboard (interlock switch, temperature sensor)
  • Potential equalization
  • EMC glands
  • Pressure compensation element
  • Short-circuit bracket

Spezifikationen:

System voltage

up to 450 VDC

Supply voltage

12 V / 24 V

Fuse protection

Positive and negative pole

System weight

11 kg (fully assembled)

Ambient temperature

-20 - +60 °C

Protection class

IP65* and IK09

* higher class on request

Datasheet (PDF)

FUSION80 : High voltage distribution unit 80 Volt

SUNCAR FUSION 80

Features:

  • 4x connections up to 150 A
  • 4x connections up to 50 A
  • 1x connections up to 160A
  • Potential equalization
  • EMC glands
  • Pressure compensation element
  • DC additional relay (optional)

Spezifikationen:

System voltage

Up to 80 VDC

Supply voltage

12 V / 24 V

Fuse protection

Positive and negative pole

System weight

6 kg (fully assembled)

Ambient temperature

-20 - +60 °C

Protection class

IP66* and IK09

* higher class on request

Datasheet (PDF)

FUSION800L : High voltage distribution unit 800 Volt

SUNCAR FUSION800L

Features:

  • 1x connections up to 600A
  • 2x connections up to 400 A
  • 18x connections up to 150 A
  • 8x connections up to 50 A
  • Mainboard (interlock switch, temperature sensor)
  • Potential equalization
  • EMC glands
  • Pressure compensation element
  • Short-circuit bracket
  • Access measuring tips with additional safety cover
  • Insulation monitor (optional)

Spezifikationen:

System voltage

Up to 800 VDC

Supply voltage

12 V / 24 V

Fuse protection

Positive and negative pole

System weight

65 kg (fully assembled)

Ambient temperature

-25 - +55 °C

Protection class

IP66

* higher class on request

Datasheet (PDF)

Are you interested in one of our products, or do you need a customization?

We accompany you from the concept to the elaboration and up to the serial product.

Contact us